1.
JACC Clin Electrophysiol ; 10(4): 718-730, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430088

RESUMO

BACKGROUND: Integrating patient-specific cardiac implantable electronic device (CIED)-detected atrial fibrillation (AF) burden with measures of health care cost and utilization allows for an accurate assessment of the AF-related impact on health care use. OBJECTIVES: The goal of this study was to assess the incremental cost of device-recognized AF vs no AF; compare relative costs of paroxysmal atrial fibrillation (pAF), persistent atrial fibrillation (PeAF), and permanent atrial fibrillation (PermAF) AF; and evaluate rates and sources of health care utilization between cohorts. METHODS: Using the de-identified Optum Clinformatics U.S. claims database (2015-2020) linked with the Medtronic CareLink database, CIED patients were identified who transmitted data ≥6 months postimplantation. Annualized per-patient costs in follow-up were analyzed from insurance claims and adjusted to 2020 U.S. dollars. Costs and rates of health care utilization were compared between patients with no AF and those with device-recognized pAF, PeAF, and PermAF. Analyses were adjusted for geographical region, insurance type, CHA2DS2-VASc score, and implantation year. RESULTS: Of 21,391 patients (mean age 72.9 ± 10.9 years; 56.3% male) analyzed, 7,798 (36.5%) had device-recognized AF. The incremental annualized increased cost in those with AF was $12,789 ± $161,749 per patient, driven by increased rates of health care encounters, adverse clinical events associated with AF, and AF-specific interventions. Among those with AF, PeAF was associated with the highest cost, driven by increased rates of inpatient and outpatient hospitalization encounters, heart failure hospitalizations, and AF-specific interventions. CONCLUSIONS: Presence of device-recognized AF was associated with increased health care cost. Among those with AF, patients with PeAF had the highest health care costs. Mechanisms for cost differentials include both disease-specific consequences and physician-directed interventions.


Assuntos
Fibrilação Atrial , Custos de Cuidados de Saúde , Aceitação pelo Paciente de Cuidados de Saúde , Humanos , Fibrilação Atrial/economia , Fibrilação Atrial/terapia , Masculino , Custos de Cuidados de Saúde/estatística & dados numéricos , Feminino , Idoso , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Estados Unidos , Desfibriladores Implantáveis/economia , Desfibriladores Implantáveis/estatística & dados numéricos , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Efeitos Psicossociais da Doença , Idoso de 80 Anos ou mais
2.
Rev. esp. cardiol. (Ed. impr.) ; 75(1): 12-21, ene. 2022. ilus, tab, ^evideo
Artigo em Espanhol | IBECS | ID: ibc-206931

RESUMO

Introducción y objetivos: El desfibrilador automático implantable (DAI) es una alternativa coste-efectiva para la prevención secundaria de la muerte súbita cardiaca, pero sigue habiendo dudas sobre su eficiencia en prevención primaria, sobre todo en pacientes con cardiopatía no isquémica.Métodos: Análisis de coste-utilidad del DAI más tratamiento médico convencional frente a tratamiento médico convencional para la prevención primaria de arritmias cardiacas desde la perspectiva del Sistema Nacional de Salud. Se simuló el curso de la enfermedad mediante modelos de Markov en pacientes con y sin cardiopatía isquémica. Los parámetros del modelo se basaron en los resultados obtenidos mediante metanálisis de los ensayos clínicos publicados entre 1996 y 2018 en los que se comparaba el DAI con el tratamiento médico convencional, los resultados de seguridad del ensayo DANISH y el análisis de la práctica clínica habitual en un hospital terciario.Resultados: Se estimó un beneficio del DAI sobre la muerte por cualquier causa con HR = 0,70 (IC95%, 0,58-0,85) en cardiopatía isquémica y HR = 0,79 (IC95%, 0,66-0,96) en no isquémica. La razón de coste-efectividad incremental estimada mediante análisis probabilístico fue de 19.171 euros/año de vida ajustado por calidad (AVAC) en pacientes con cardiopatía isquémica, 31.084 euros/AVAC en pacientes con miocardiopatía dilatada no isquémica y 23.230 euros/AVAC en los menores de 68 años.Conclusiones: La eficiencia del DAI monocameral ha mejorado en la última década y este resulta coste-efectivo para los pacientes con disfunción ventricular izquierda de origen isquémico o no isquémico menores de 68 años considerando una disposición a pagar 25.000 euros/AVAC. En pacientes no isquémicos mayores, la razón de coste-efectividad incremental estimada se sitúa alrededor de los 30.000 euros/AVAC (AU)


Introduction and objective: Implantable cardioverter-defibrillators (ICD) are a cost-effective alternative for secondary prevention of sudden cardiac death, but their efficiency in primary prevention, especially among patients with nonischemic heart disease, is still uncertain.Methods: We performed a cost-effectiveness analysis of ICD plus conventional medical treatment (CMT) vs CMT for primary prevention of cardiac arrhythmias from the perspective of the national health service. We simulated the course of the disease by using Markov models in patients with ischemic and nonischemic heart disease. The parameters of the model were based on the results obtained from a meta-analysis of clinical trials published between 1996 and 2018 comparing ICD plus CMT vs CMT, the safety results of the DANISH trial, and analysis of real-world clinical practice in a tertiary hospital.Results: We estimated that ICD reduced the likelihood of all-cause death in patients with ischemic heart disease (HR, 0.70; 95%CI, 0.58-0.85) and in those with nonischemic heart disease (HR, 0.79; 95%CI, 0.66–0.96). The incremental cost-effectiveness ratio (ICER) estimated with probabilistic analysis was €19 171/quality adjusted life year (QALY) in patients with ischemic heart disease and €31 084/QALY in those with nonischemic dilated myocardiopathy overall and €23 230/QALY in patients younger than 68 years.Conclusions: The efficiency of single-lead ICD systems has improved in the last decade, and these devices are cost-effective in patients with ischemic and nonischemic left ventricular dysfunction younger than 68 years, assuming willingness to pay as €25 000/QALY. For older nonischemic patients, the ICER was around €30 000/QALY (AU)


Assuntos
Humanos , Animais , Masculino , Feminino , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Isquemia Miocárdica/terapia , Análise Custo-Benefício , Prevenção Primária , Medicina Estatal , Cadeias de Markov
3.
J Am Heart Assoc ; 10(16): e021144, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34387130

RESUMO

Background Optimal management of asymptomatic Brugada syndrome (BrS) with spontaneous type I electrocardiographic pattern is uncertain. Methods and Results We developed an individual-level simulation comprising 2 000 000 average-risk individuals with asymptomatic BrS and spontaneous type I electrocardiographic pattern. We compared (1) observation, (2) electrophysiologic study (EPS)-guided implantable cardioverter-defibrillator (ICD), and (3) upfront ICD, each using either subcutaneous or transvenous ICD, resulting in 6 strategies tested. The primary outcome was quality-adjusted life years (QALYs), with cardiac deaths (arrest or procedural-related) as a secondary outcome. We varied BrS diagnosis age and underlying arrest rate. We assessed cost-effectiveness at $100 000/QALY. Compared with observation, EPS-guided subcutaneous ICD resulted in 0.35 QALY gain/individual and 4130 cardiac deaths avoided/100 000 individuals, and EPS-guided transvenous ICD resulted in 0.26 QALY gain and 3390 cardiac deaths avoided. Compared with observation, upfront ICD reduced cardiac deaths by a greater margin (subcutaneous ICD, 8950; transvenous ICD, 6050), but only subcutaneous ICD improved QALYs (subcutaneous ICD, 0.25 QALY gain; transvenous ICD, 0.01 QALY loss), and complications were higher. ICD-based strategies were more effective at younger ages and higher arrest rates (eg, using subcutaneous devices, upfront ICD was the most effective strategy at ages 20-39.4 years and arrest rates >1.37%/year; EPS-guided ICD was the most effective strategy at ages 39.5-51.3 years and arrest rates 0.47%-1.37%/year, and observation was the most effective strategy at ages >51.3 years and arrest rates <0.47%/year). EPS-guided subcutaneous ICD was cost-effective ($80 508/QALY). Conclusions Device-based approaches (with or without EPS risk stratification) can be more effective than observation among selected patients with asymptomatic BrS. BrS management should be tailored to patient characteristics.


Assuntos
Síndrome de Brugada/terapia , Técnicas de Apoio para a Decisão , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Adulto , Doenças Assintomáticas , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/economia , Síndrome de Brugada/mortalidade , Pesquisa Comparativa da Efetividade , Análise Custo-Benefício , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/economia , Cardioversão Elétrica/mortalidade , Eletrocardiografia , Custos de Cuidados de Saúde , Humanos , Pessoa de Meia-Idade , Modelos Econômicos , Anos de Vida Ajustados por Qualidade de Vida , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
5.
Am Heart J ; 235: 44-53, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33503408

RESUMO

BACKGROUND: Whether insurance status influences practice patterns in implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) defibrillators, when indicated, is not known. METHODS AND RESULTS: We analyzed the NCDR ICD Registry to evaluate associations of insurance status with guidelines-based receipt of CRT, as well as device-type, complication rates, and use of optimal medical therapy defined by guidelines. Among 798,028 patients with de novo ICD implants, we included only patients < 65 years (those older have Medicare) and excluded those admitted before 2006 (n=1,835) or with insurance coverage other than Medicare, Medicaid or private insurance (n=25,695) leaving 286,556 for analysis. Inverse probability of treatment weighting was used to control for imbalances between groups. Mean age was 53 years, 29% were female. Patients with private insurance and Medicare were more likely to receive CRT-D when indicated (79.6%, OR 1.19 95% CI 1.09-1.28, P <.001 and 78.5%, OR 1.11 95% CI 1.01-1.21 P = .03, respectively) compared to the uninsured (76.7%). The uninsured were also more likely than other groups to receive a single-chamber device. Complication rates did not differ. Uninsured patients were, however, more likely to receive optimal medical therapy, particularly in the subgroup receiving the implant for primary prevention. CONCLUSIONS: In propensity-weighted analysis, uninsured patients are less likely to receive CRT when indicated but more likely to be receiving optimal medical therapy at discharge. Reasons for differences in device implantation practices based on insurance status require further study.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/terapia , Cobertura do Seguro/economia , Prevenção Primária/métodos , Sistema de Registros , Feminino , Insuficiência Cardíaca/economia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
JAMA ; 324(17): 1755-1764, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33141208

RESUMO

Importance: Little is known about the association between industry payments and medical device selection. Objective: To examine the association between payments from device manufacturers to physicians and device selection for patients undergoing first-time implantation of a cardioverter-defibrillator (ICD) or cardiac resynchronization therapy-defibrillator (CRT-D). Design, Setting, and Participants: In this cross-sectional study, patients who received a first-time ICD or CRT-D device from any of the 4 major manufacturers (January 1, 2016-December 31, 2018) were identified. The data from the National Cardiovascular Data Registry ICD Registry was linked with the Open Payments Program's payment data. Patients were categorized into 4 groups (A, B, C, and D) corresponding to the manufacturer from which the physician who performed the implantation received the largest payment. For each patient group, the proportion of patients who received a device from the manufacturer that provided the largest payment to the physician who performed implantation was determined. Within each group, the absolute difference in proportional use of devices between the manufacturer that made the highest payment and the proportion of devices from the same manufacturer in the entire study cohort (expected prevalence) was calculated. Exposures: Manufacturers' payments to physicians who performed an ICD or CRT-D implantation. Main Outcomes and Measures: The primary outcome of the study was the manufacturer of the device used for the implantation. Results: Over a 3-year period, 145 900 patients (median age, 65 years; 29.6% women) received ICD or CRT-D devices from the 4 manufacturers implanted by 4435 physicians at 1763 facilities. Among these physicians, 4152 (94%) received payments from device manufacturers ranging from $2 to $323 559 with a median payment of $1211 (interquartile range, $390-$3702). Between 38.5% and 54.7% of patients received devices from the manufacturers that had provided physicians with the largest payments. Patients were substantially more likely to receive devices made by the manufacturer that provided the largest payment to the physician who performed implantation than they were from each other individual manufacturer. The absolute differences in proportional use from the expected prevalence were 22.4% (95% CI, 21.9%-22.9%) for manufacturer A; 14.5% (95% CI, 14.0%-15.0%) for manufacturer B; 18.8% (95% CI, 18.2%-19.4%) for manufacturer C; and 30.6% (95% CI, 30.0%-31.2%) for manufacturer D. Conclusions and Relevance: In this cross-sectional study, a large proportion of ICD or CRT-D implantations were performed by physicians who received payments from device manufacturers. Patients were more likely to receive ICD or CRT-D devices from the manufacturer that provided the highest total payment to the physician who performed an ICD or CRT-D implantation than each other manufacturer individually.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Renda , Indústria Manufatureira/economia , Médicos/economia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Estudos Transversais , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Humanos , Masculino , Indústria Manufatureira/classificação , Sistema de Registros
7.
Circ Arrhythm Electrophysiol ; 13(10): e008503, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32915063

RESUMO

BACKGROUND: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. METHODS: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. RESULTS: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. CONCLUSIONS: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Implantação de Prótese/economia , Infecções Relacionadas à Prótese/economia , Implantes Absorvíveis/economia , Antibacterianos/uso terapêutico , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Redução de Custos , Análise Custo-Benefício , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Humanos , Modelos Econômicos , Estudos Multicêntricos como Assunto , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
8.
Pediatr Cardiol ; 41(7): 1484-1491, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32623612

RESUMO

Children at high risk for sudden cardiac death (SCD) receive implantable cardioverter-defibrillators (ICD) for prevention, but the cost effectiveness of ICDs in children at intermediate risk is unclear. Our objective was to create a cost-effectiveness model to compare costs and outcomes in children at risk of SCD, with and without ICD. Utilizing hypertrophic cardiomyopathy as the proxy disease, a theoretical cohort of 8150 children was followed for 69 years. Model inputs were derived from the literature, with an incremental cost-effectiveness ratio (ICER) willingness-to-pay threshold of $100,000/quality-adjusted life year (QALY) used to delineate cost effectiveness. Outcomes included prevalence of severe neurological morbidity (SNM), SCD, cost, and QALYs. In children at intermediate risk of SCD (4-6% over 5 years), ICD resulted in 56 fewer cases of SNM, 2686 fewer deaths. In children at high risk (> 6% over 5 years), ICD placement resulted in 74 fewer cases of SNM and 3663 fewer deaths from cardiac causes. The costs of ICD were higher, but placement was cost effective with an ICER of $3009 per QALY in intermediate risk children, but ICD therapy was a dominant strategy in high-risk children. Sensitivity analysis demonstrated ICD placement was cost-effective until the annual probability of SCD was < 0.22%. The model was robust over a wide range of values. For children at risk of SCD, prophylactic ICD implantation is cost effective, resulting in improved outcomes and increased QALYs, despite increased costs. These findings highlight the economic benefits of ICD utilization in this population.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Anos de Vida Ajustados por Qualidade de Vida , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/cirurgia , Criança , Análise Custo-Benefício , Morte Súbita Cardíaca/etiologia , Humanos , Cadeias de Markov
9.
J Comp Eff Res ; 9(10): 659-666, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32639168

RESUMO

Aim: The study assesses the burden and costs of recurring unexplained syncope and injuries and the effectiveness of implantable loop recorders. Methods: The English national hospital database (Hospital Episode Statistics) was retrospectively analyzed. Results: 12,002 patients were identified with repeated syncope hospitalizations. 25% of patients were hospitalized at least once again for syncope, 9% of the patients were hospitalized at least once for an injury, causing substantial costs. In the second analysis: 10,902 patients implanted with an implantable cardiac monitor were tracked. By year 3, hospitalizations due to syncope had dropped by 60% versus pre-implantable cardiac monitor (ICM) levels. Conclusion: This study shows a high rate of recurrent syncope admissions and a parallel burden of hospitalizations for injuries. Use of an ICM appears to reduce syncope hospitalizations.


Assuntos
Desfibriladores Implantáveis/economia , Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca/fisiologia , Hospitalização/economia , Marca-Passo Artificial/economia , Síncope/terapia , Eletrocardiografia , Feminino , Custos de Cuidados de Saúde , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/epidemiologia , Resultado do Tratamento
10.
Heart Rhythm ; 17(11): 1917-1921, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32526349

RESUMO

BACKGROUND: National trends and costs associated with remote and in-office interrogations of pacemakers and implantable cardioverter-defibrillators (ICDs) have not been previously described. OBJECTIVE: The purpose of this study was to evaluate utilization and Medicare spending for remote monitoring and in-office interrogations for pacemakers and ICDs. METHODS: We performed a retrospective cohort study of claims and spending for remote and in-office interrogations of pacemakers and ICDs for Medicare fee-for-service beneficiaries from 2012 to 2015. Aggregate and per-beneficiary claims and spending were calculated for each device type. RESULTS: Among all patients, 41.9% were female and the mean age was 78.3 years. From 2012 to 2015, remote monitoring utilization increased sharply. Aggregate professional remote monitoring claims for pacemakers increased by 61.3% and for ICDs by 5.6%, with an increase in technical claims (combined for pacemakers and ICDs) of 32.8%. Spending on all remote and in-office interrogations for these devices totaled $160 million per year, with remote costs increasing nearly 25% from $45.4 million in 2012 to $56.7 million in 2015. At the beneficiary level, remote interrogations increased for pacemakers from 0.6 to 0.9 per year, and for ICDs from 1.3 to 1.4 per year, whereas in-office interrogations decreased from 2.8 to 2.7 per year and from 3.0 to 2.9 per year, respectively. Beneficiary-level analysis revealed increased expenditures on remote interrogation offset by decreases in in-office expenditures, with total annual spending decreasing by $2 and $5 per beneficiary, respectively. CONCLUSION: Remote monitoring utilization increased substantially from 2012 to 2015, whereas annual costs per beneficiary decreased.


Assuntos
Desfibriladores Implantáveis/economia , Gastos em Saúde/estatística & dados numéricos , Medicare/estatística & dados numéricos , Monitorização Fisiológica/economia , Marca-Passo Artificial/economia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Monitorização Fisiológica/métodos , Estudos Retrospectivos , Estados Unidos
11.
Circ Arrhythm Electrophysiol ; 13(5): e008280, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32281393

RESUMO

BACKGROUND: Current understanding of the impact of cardiac implantable electronic device (CIED) infection is based on retrospective analyses from medical records or administrative claims data. The WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) offers an opportunity to evaluate the clinical and economic impacts of CIED infection from the hospital, payer, and patient perspectives in the US healthcare system. METHODS: This was a prespecified, as-treated analysis evaluating outcomes related to major CIED infections: mortality, quality of life, disruption of CIED therapy, healthcare utilization, and costs. Payer costs were assigned using medicare fee for service national payments, while medicare advantage, hospital, and patient costs were derived from similar hospital admissions in administrative datasets. RESULTS: Major CIED infection was associated with increased all-cause mortality (12-month risk-adjusted hazard ratio, 3.41 [95% CI, 1.81-6.41]; P<0.001), an effect that sustained beyond 12 months (hazard ratio through all follow-up, 2.30 [95% CI, 1.29-4.07]; P=0.004). Quality of life was reduced (P=0.004) and did not normalize for 6 months. Disruptions in CIED therapy were experienced in 36% of infections for a median duration of 184 days. Mean costs were $55 547±$45 802 for the hospital, $26 867±$14 893, for medicare fee for service and $57 978±$29 431 for Medicare Advantage (mean hospital margin of -$30 828±$39 757 for medicare fee for service and -$6055±$45 033 for medicare advantage). Mean out-of-pocket costs for patients were $2156±$1999 for medicare fee for service, and $1658±$1250 for medicare advantage. CONCLUSIONS: This large, prospective analysis corroborates and extends understanding of the impact of CIED infections as seen in real-world datasets. CIED infections severely impact mortality, quality of life, healthcare utilization, and cost in the US healthcare system. Registration: URL: https://www.clinicaltrials.gov Unique Identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibacterianos/uso terapêutico , Antibioticoprofilaxia/economia , Desfibriladores Implantáveis/economia , Custos de Cuidados de Saúde , Recursos em Saúde/economia , Marca-Passo Artificial/economia , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/efeitos adversos , Antibioticoprofilaxia/efeitos adversos , Causas de Morte , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/economia , Custos de Medicamentos , Planos de Pagamento por Serviço Prestado/economia , Feminino , Gastos em Saúde , Custos Hospitalares , Humanos , Tempo de Internação/economia , Masculino , Medicare/economia , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Readmissão do Paciente/economia , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Qualidade de Vida , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
12.
Heart Rhythm ; 17(8): 1328-1334, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32234558

RESUMO

BACKGROUND: Children at high risk for sudden cardiac death (SCD) (>6% over 5 years) receive an implantable cardioverter-defibrillator (ICD), but no guidelines are available for those at lower risk. For children at intermediate risk for SCD (4%-6% over 5 years), the utility and cost-effectiveness of in-home automated external defibrillators (AEDs) are unclear. OBJECTIVE: The purpose of this study was to assess the cost-effectiveness of in-home AED for children at intermediate risk for SCD. METHODS: Using hypertrophic cardiomyopathy (HCM) as the proxy disease, a theoretical cohort of 1550 ten-year-old children with HCM was followed for 69 years. Baseline annual risk of SCD was 0.8%. Outcomes were SCD, severe neurologic morbidity (SNM), cost, and quality-adjusted life-years (QALYs). Model inputs were derived from the literature, with a willingness-to-pay threshold of $100,000 per QALY. RESULTS: Among children at intermediate risk for SCD, in-home AED resulted in 31 fewer cases of SCD but 3 more cases of SNM. There were 319 QALYs gained. Although costs were higher by $28 million, the incremental cost-effectiveness ratio was $86,458, which is below the willingness-to-pay threshold. CONCLUSION: For children at intermediate risk for SCD and HCM, in-home AED is cost-effective, resulting in fewer deaths and increased QALYS for a cost below the willingness-to-pay threshold. These findings highlight the economic benefits of in-home AED use in this population.


Assuntos
Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Anos de Vida Ajustados por Qualidade de Vida , Cardiomiopatia Hipertrófica/complicações , Criança , Análise Custo-Benefício , Morte Súbita Cardíaca/epidemiologia , Técnicas de Apoio para a Decisão , Feminino , Humanos , Masculino , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
13.
J Med Econ ; 23(7): 690-697, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32207659

RESUMO

Aims: Heart failure with reduced ejection fraction (HFrEF) has a substantial impact on costs and patients' quality-of-life. This study aimed to estimate the cost-effectiveness of implantable cardioverter defibrillators (ICD), cardiac resynchronization therapy pacemakers (CRT-P), cardiac resynchronization therapy defibrillators (CRT-D), and optimal pharmacologic therapy (OPT) in patients with HFrEF, from a US payer perspective.Materials and methods: The analyses were conducted by adapting the UK-based cost-effectiveness analyses (CEA) to the US payer perspective by incorporating real world evidence (RWE) on baseline hospitalization risk and Medicare-specific costs. The CEA was based on regression equations estimated from data from 13 randomized clinical trials (n = 12,638). Risk equations were used to predict all-cause mortality, hospitalization rates, health-related quality-of-life, and device-specific treatment effects (vs. OPT). These equations included the following prognostic characteristics: age, QRS duration, New York Heart Association (NYHA) class, ischemic etiology, and left bundle branch block (LBBB). Baseline hospitalization rates were calibrated based on RWE from Truven Health Analytics MarketScan data (2009-2014). A US payer perspective, lifetime time horizon, and 3% discount rates for costs and outcomes were used. Benefits were expressed as quality-adjusted life-years (QALYs). Incremental cost-effectiveness analysis was conducted for 24 sub-groups based on LBBB status, QRS duration, and NYHA class.Results: Results of the analyses show that CRT-D was the most cost-effective treatment at a $100,000/QALY threshold in 14 of the 16 sub-groups for which it is indicated. Results were most sensitive to changes in estimates of hospitalization costs.Limitations: Study limitations include small sample sizes for NYHA I and IV sub-groups and lack of data availability for duration of treatment effect.Conclusions: CRT-D has higher greater cost-effectiveness across more sub-groups in the indicated patient populations against as compared to OPT, ICD, and CRT-P, from a US payer perspective.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Análise Custo-Benefício , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca Sistólica/tratamento farmacológico , Insuficiência Cardíaca Sistólica/cirurgia , Idoso , Bases de Dados Factuais , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Medicare , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Estudos Retrospectivos , Estados Unidos
14.
Open Heart ; 7(1): e001155, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32076562

RESUMO

Objective: Catheter ablation is an important treatment for ventricular tachycardia (VT) that reduces the frequency of episodes of VT. We sought to evaluate the cost-effectiveness of catheter ablation versus antiarrhythmic drug (AAD) therapy. Methods: A decision-analytic Markov model was used to calculate the costs and health outcomes of catheter ablation or AAD treatment of VT for a hypothetical cohort of patients with ischaemic cardiomyopathy and an implantable cardioverter-defibrillator. The health states and input parameters of the model were informed by patient-reported health-related quality of life (HRQL) data using randomised clinical trial (RCT)-level evidence wherever possible. Costs were calculated from a 2018 UK perspective. Results: Catheter ablation versus AAD therapy had an incremental cost-effectiveness ratio (ICER) of £144 150 (€161 448) per quality-adjusted life-year gained, over a 5-year time horizon. This ICER was driven by small differences in patient-reported HRQL between AAD therapy and catheter ablation. However, only three of six RCTs had measured patient-reported HRQL, and when this was done, it was assessed infrequently. Using probabilistic sensitivity analyses, the likelihood of catheter ablation being cost-effective was only 11%, assuming a willingness-to-pay threshold of £30 000 used by the UK's National Institute for Health and Care Excellence. Conclusion: Catheter ablation of VT is unlikely to be cost-effective compared with AAD therapy based on the current randomised trial evidence. However, better designed studies incorporating detailed and more frequent quality of life assessments are needed to provide more robust and informed cost-effectiveness analyses.


Assuntos
Antiarrítmicos/economia , Antiarrítmicos/uso terapêutico , Cardiomiopatias/complicações , Ablação por Cateter/economia , Custos de Cuidados de Saúde , Isquemia Miocárdica/complicações , Taquicardia Ventricular/economia , Taquicardia Ventricular/terapia , Idoso , Antiarrítmicos/efeitos adversos , Cardiomiopatias/diagnóstico , Cardiomiopatias/economia , Cardiomiopatias/terapia , Ablação por Cateter/efeitos adversos , Análise Custo-Benefício , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Cardioversão Elétrica/economia , Cardioversão Elétrica/instrumentação , Medicina Baseada em Evidências/economia , Feminino , Humanos , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Modelos Econômicos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/economia , Isquemia Miocárdica/terapia , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto/economia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 31(2): 503-511, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31916328

RESUMO

BACKGROUND: Cardiac implantable electronic device transvenous (TV) lead reoperations are projected to increase, and robust economic data are needed to assess the resulting financial impact and the cost-effectiveness of prevention and treatment strategies. This study estimates Medicare costs, and describes patterns of complications, in patients who underwent TV lead reoperation. METHODS AND RESULTS: Medicare data (2010-2014) were used to identify patients who underwent TV lead reoperation. Cumulative costs to Medicare, and rates of infection and mechanical complications were calculated from 180 days before, to 180 days after, lead reoperation. Multivariate analysis was used to estimate adjusted costs, and to examine the impact of complications on medical resource use and costs. There were 1691 patients, 63.2% of whom underwent inpatient lead reoperation. Overall, the mean age was 78.2 years, 39.6% were female, and 92.3% were white. The mean cumulative cost was $36 199 (95% confidence interval [CI], $31 864-$40 535) for TV lead repositioning, $27 701 (95% CI, $19 869-$35 534) for repair, and $54 442 (95% CI, $51 651-$57 233) for removal. Underlying infection was associated with increased odds of inpatient reoperation and of lead removal, as well as longer length of stay and higher costs. CONCLUSIONS: The economic consequences of TV lead reoperation are substantial. Strategies aimed at reducing reoperation, particularly lead removal, are likely to result in considerable cost offsets.


Assuntos
Desfibriladores Implantáveis/economia , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/economia , Custos de Cuidados de Saúde , Recursos em Saúde/economia , Marca-Passo Artificial/economia , Complicações Pós-Operatórias/economia , Complicações Pós-Operatórias/terapia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/mortalidade , Feminino , Humanos , Tempo de Internação/economia , Masculino , Medicare/economia , Complicações Pós-Operatórias/mortalidade , Reoperação/efeitos adversos , Reoperação/economia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
16.
Clin Microbiol Infect ; 26(2): 255.e1-255.e6, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30797886

RESUMO

The rate of cardiac implantable electronic device (CIED) infection is increasing with time. We sought to determine the predictors, relative mortality, and cost burden of early-, mid- and late-onset CIED infections. We conducted a retrospective cohort study of all CIED implantations in Ontario, Canada between April 2013 and March 2016. The procedures and infections were identified in validated, population-wide health-care databases. Infection onset was categorized as early (0-30 days), mid (31-182 days) and late (183-365 days). Cox proportional hazards regression was used to assess the mortality impact of CIED infections, with infection modelled as a time-varying covariate. A generalized linear model with a log-link and γ distribution was used to compare health-care system costs by infection status. Among 17 584 patients undergoing CIED implantation, 215 (1.2%) developed an infection, including 88 early, 85 mid, and 42 late infections. The adjusted hazard ratio (aHR) of death was higher for patients with early (aHR 2.9, 95% CI 1.7-4.9), mid (aHR 3.3, 95% CI 1.9-5.7) and late (aHR 19.9, 95% CI 9.9-40.2) infections. Total mean 1-year health costs were highest for late-onset (mean Can$113 778), followed by mid-onset (mean Can$85 302), and then early-onset (Can$75 415) infections; costs for uninfected patients were Can$25 631. After accounting for patient and procedure characteristics, there was a significant increase in costs associated with early- (rate ratio (RR) 3.1, 95% CI 2.3-4.1), mid- (RR 2.8, 95% CI 2.4-3.3) and late- (RR 4.7, 95% CI 3.6-6.2) onset infections. In summary, CIED infections carry a tremendous clinical and economic burden, and this burden is disproportionately high for late-onset infections.


Assuntos
Efeitos Psicossociais da Doença , Desfibriladores Implantáveis/economia , Cardiopatias/economia , Marca-Passo Artificial/economia , Infecções Relacionadas à Prótese/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/microbiologia , Feminino , Custos de Cuidados de Saúde , Cardiopatias/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Marca-Passo Artificial/microbiologia , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica/economia
17.
Heart Rhythm ; 17(2): 287-293, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31476408

RESUMO

BACKGROUND: Dilated cardiomyopathy (DCM) is the most common cardiomyopathy in children. Patients with severe cardiac dysfunction are thought to be at risk of sudden cardiac arrest (SCA). After diagnosis, a period of medical optimization is recommended before permanent implantable cardioverter-defibrillator (ICD) implantation. Wearable cardioverter-defibrillators (WCDs) provide an option for arrhythmia protection as an outpatient during this optimization. OBJECTIVE: The purpose of this study was to determine the strategy that optimizes cost and survival during medical optimization of a patient with DCM before ICD placement. METHODS: A Markov state transition model was constructed for the 3 clinical approaches to compare costs, clinical outcomes, and quality of life: (1) "Inpatient," (2) "Home-WCD," and (3) "Home-No WCD." Transitional probabilities, costs, and utility metrics were extracted from the existing literature. Cost-effectiveness was assessed comparing each paradigm's incremental cost-effectiveness ratio against a societal willingness-to-pay threshold of $50,000 per quality-adjusted life year. RESULTS: The cost-utility analysis illustrated that Home-WCD met the willingness-to-pay threshold with an incremental cost-effectiveness ratio of $20,103 per quality-adjusted life year and 4 mortalities prevented per 100 patients as compared with Home-No WCD. One-way sensitivity analyses demonstrated that Home-No WCD became the most cost-effective solution when the probability of SCA fell below 0.2% per week, the probability of SCA survival with a WCD fell below 9.8%, or the probability of SCA survival with Home-No WCD quadrupled from base-case assumptions. CONCLUSION: Based on the existing literature probabilities of SCA in pediatric patients with DCM undergoing medical optimization before ICD implantation, sending a patient home with a WCD may be a cost-effective strategy.


Assuntos
Arritmias Cardíacas/terapia , Cardiomiopatias/terapia , Desfibriladores Implantáveis/economia , Qualidade de Vida , Dispositivos Eletrônicos Vestíveis/economia , Arritmias Cardíacas/etiologia , Cardiomiopatias/complicações , Criança , Análise Custo-Benefício , Humanos
18.
Heart Lung Circ ; 29(7): e140-e146, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31839364

RESUMO

BACKGROUND: Implantable cardiac electronic device (ICED) infections are associated with significant morbidity, mortality and cost. The aim of this study was to perform the first analysis for the cost of ICED infection in Australia. Secondary aims were to provide an update on the incidence, burden and outcomes of ICED infections and an analysis of the hospital ICD-10 codes used for ICED infection admissions. METHODS: We performed a retrospective study of ICED implantations and infections in the Barwon Health region (BH) and the state of Victoria (Vic) from January 2010 to December 2015 inclusive. RESULTS: Sensitivity of ICD-10 code T82.7 was 63.4% (95% CI 46.9-77.8) and specificity was 14.5% (95% CI 9.9-21.1). Infection rates were 1.4 admissions/100,000 persons/year (SD 0.7) in BH and estimated to be 7.9 admissions/100,000 persons/year (95% CI 6.8-9.0) in Vic. Average cost of infection was $670,334/year in BH and estimated to be $14,879,979/year in Vic. CONCLUSION: Rates of ICED infection are decreasing in Victoria. Infections are associated with significant morbidity and cost.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/economia , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/economia , Idoso , Custos e Análise de Custo , Desfibriladores Implantáveis/economia , Feminino , Humanos , Incidência , Masculino , Marca-Passo Artificial/economia , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Vitória/epidemiologia
19.
Pharmacoeconomics ; 38(3): 285-296, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31755032

RESUMO

BACKGROUND: Clinical trials often report intervention efficacy in terms of the reduction in all-cause mortality between the treatment and control arms (i.e., an overall hazard ratio [oHR]) instead of the reduction in disease-specific mortality (i.e., a disease-specific hazard ratio [dsHR]). Using oHR to reduce all-cause mortality beyond the time horizon of the trial may introduce bias if the relative proportion of other-cause mortality increases with age. We sought to quantify this oHR extrapolation bias and propose a new approach to overcome this bias. METHODS: We simulated a hypothetical cohort of patients with a generic disease that increased background mortality by a constant additive disease-specific rate. We quantified the bias in terms of the percentage change in life expectancy gains with the intervention under an oHR compared with a dsHR approach as a function of the cohort start age, the disease-specific mortality rate, dsHR, and the duration of the intervention's effect. We then quantified the bias in a cost-effectiveness analysis (CEA) of implantable cardioverter-defibrillators based on efficacy estimates from a clinical trial. RESULTS: For a cohort of 50-year-old patients with a disease-specific mortality of 0.05, a dsHR of 0.5, a calculated oHR of 0.55, and a lifetime duration of effect, the bias was 28%. We varied these key parameters over wide ranges and the resulting bias ranged between 3 and 140%. In the CEA, the use of oHR as the intervention's effectiveness overestimated quality-adjusted life expectancy by 9% and costs by 3%, biasing the incremental cost-effectiveness ratio by - 6%. CONCLUSIONS: The use of an oHR approach to model the intervention's effectiveness beyond the time horizon of the trial overestimates its benefits. In CEAs, this bias could decrease the cost of a QALY, overestimating interventions' cost effectiveness.


Assuntos
Desfibriladores Implantáveis/economia , Modelos Econômicos , Mortalidade/tendências , Infarto do Miocárdio/economia , Avaliação de Resultados em Cuidados de Saúde/economia , Viés , Análise Custo-Benefício , Tomada de Decisões , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Modelos de Riscos Proporcionais , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto/economia
20.
Biomedica ; 39(3): 502-512, 2019 09 01.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31584764

RESUMO

INTRODUCTION: The use of an implantable cardioverter-defibrillator reduces the probability of sudden cardiac death in patients with heart failure. OBJECTIVE: To determine the cost-utility relationship of an implantable cardioverter-defibrillator compared to optimal pharmacological therapy for patients with ischemic or non-ischemic New York Heart Association class II or III (NYHA II-III) heart failure in Colombia. MATERIALS AND METHODS: We developed a Markov model including costs, effectiveness, and quality of life from the perspective of the Colombian health system. For the baseline case, we adopted a time horizon of 10 years and discount rates of 3% for costs and 3.5% for benefits. The transition probabilities were obtained from a systematic review of the literature. The outcome used was the quality-adjusted life years. We calculated the costs by consulting with the manufacturers of the device offered in the Colombian market and using national-level pricing manuals. We conducted probabilistic and deterministic sensitivity analyses. RESULTS: In the base case, the incremental cost-effectiveness ratio for the implantable cardioverter-defibrillator was USD$ 13,187 per quality-adjusted life year gained. For a willingness-to-pay equivalent to three times the gross domestic product per capita as a reference (USD$ 19,139 in 2017), the device would be a cost-effective strategy for the Colombian health system. However, the result may change according to the time horizon, the probability of death, and the price of the device. CONCLUSIONS: The use of an implantable cardioverter-defibrillator for preventing sudden cardiac death in patients with heart failure would be a cost-effective strategy for Colombia. The results should be examined considering the uncertainty.


Introducción. El uso del desfibrilador cardioversor implantable reduce la probabilidad de muerte súbita en pacientes con insuficiencia cardíaca. Objetivo. Determinar la relación de costo-utilidad de un desfibrilador cardioversor implantable comparado con la terapia farmacológica óptima para pacientes con insuficiencia cardíaca isquémica o no isquémica de clase II o III según la New York Heart Association (NYHA II-III) en Colombia. Materiales y métodos. Se desarrolló un modelo de Markov que incluyó los costos, la efectividad y la calidad de vida desde la perspectiva del sistema de salud colombiano. Para el caso de base, se adoptó un horizonte temporal de 10 años y una tasa de descuento de 3 % para los costos y de una 3,5 % para los beneficios. Las probabilidades de transición se obtuvieron de una revisión sistemática de la literatura. Los años de vida ajustados por calidad se usaron como resultado de salud. Para estimar los costos unitarios se usaron manuales tarifarios nacionales y, para los costos del dispositivo, se consultó a los fabricantes que lo comercializan en el mercado colombiano. Se hicieron análisis de sensibilidad probabilísticos y determinísticos. Resultados. En el caso base el costo adicional por año de vida ajustado por calidad ganado con el desfibrilador cardioversor implantable fue de USD$ 13,187. Usando un umbral de tres veces el producto interno bruto per cápita como referencia (USD$ 19.139 en 2017), el dispositivo sería costo-efectivo para el sistema de salud colombiano. Sin embargo, este resultado depende del horizonte temporal, de la probabilidad de muerte y del precio del dispositivo. Conclusiones. El uso de un desfibrilador cardioversor implantable sería una estrategia costo-efectiva para Colombia, aunque los resultados deben examinarse teniendo en cuenta la incertidumbre.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/terapia , Anos de Vida Ajustados por Qualidade de Vida , Colômbia , Análise Custo-Benefício , Árvores de Decisões , Insuficiência Cardíaca/classificação , Humanos , Metanálise como Assunto , Pessoa de Meia-Idade , Programas Nacionais de Saúde/economia , Qualidade de Vida , Revisões Sistemáticas como Assunto , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS